Category: Fire-Rated Doors

24″ x 36″ Fire Rated Un-Insulated Recessed Door for Drywall – BEST

24
Check Price for 24

24″ x 36″ Fire Rated Un-Insulated Recessed Door for Drywall Walls The BA-FB-5015 recessed for drywall, fire rated access door is designed for installation in drywall walls requiring concealing of the door panel consistent to the surrounding walls. The door panel is supplied with 5/8″ drywall. The Acudor FB-5015 is approved by Underwriter’s Laboratories (UL) for 1-1/2 hours “B” label in walls. Designed to maintain continuity in a 2 hour fire barrier wall, the BA-FB-5015 should be used whenever it is necessary to provide access in fire rated drywall walls, where it is required to conceal the door panel. – Application: – For installation in drywall walls requiring concealing of the door panel consistent to surrounding walls- Designed for openings that require a 1 1/2 hour fire rating when temperature rise is not a factor. Product Features – Recessed reinforced door fitted with 5/8″ drywall (supplied with door).- Concealed hinge, Self-closing, Self-latching- Inside latch release- Frame flange with pre-punched holes and textured for convenient mounting and accepting skim coat finish. BA-FB-5015 Access Door Specifications: – Door: Steel-22 Gauge recessed fitted with 5/8″ thick drywall suitable to accept skim coat finish on site- Door Frame: Steel-22 Gauge press bent for strength and rigidity with pre-punched flanges for convenient mounting and accepting skim coat finish on site- Hinge: Concealed- Fire Rating (Walls): Meets 11/2 hour fire rating requirement in accordance with Underwriters Laboratories UL 10(b) and CAN/ULC S104-10 for max size upto 24″ x 36″- Latch: Self-latching bolt, operated by flush key- Finish: Satin coat steel.

Fire Access Doors BA-PFI 12 x 22 Insulated with Flange – BEST

Fire Access Doors BA-PFI 12 x 22 Insulated with Flange - BEST
Check Price for Fire Access Doors BA-PFI 12 x 22 Insulated with Flange - BEST

12″ x 22″ – Fire Rated Insulated Access Door with Flange. BA-PFI access Hatch is insulated with 2″ thick mineral wool and can be used on fire rated walls and ceilings. It comes with a 1″ flange for an easy flush installation on any type of surface. As per UL and NFPA standards, once the installation is complete and the provided springs are hooked to the back of the panel, the door will be self closing and self locking. The largest fire rated PFI doors available for vertical and horizontal installations with temperature rise are respectively: (48″ x 48″ ) and (24″ x 36″ or 864 sq inches). BA-PFI fire rated access Panel specifications, Material: 16 gauge cold rolled steel frame and 20 gauge galvanneal steel door Insulation: 2″ mineral wool Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat . Fire Rating: For installation in vertical wall assemblies: Rating 1 1/2 hours. Temperature rise: 250 deg F (139 deg C) at 30 mins and 450 deg F (250 deg C) at 60 mins. Maximum door size of 48″ x 48″. Rating 3 hours. Temperature rise: 400 deg F at 60 mins. Maximum door size of 48″ x 48″. For installation in horizontal ceiling assemblies: With temperature rise: Rating 3 hours for non-cumbustible assembly and 1 hour for combustible assembly: Temperature rise: Max 250 deg F (139 deg C) at 30 mins, 450 deg F (250 deg C) at 60 mins. Without temperature rise: Rating: 3 hours for non-combustible assembly and 1 hour for combustible assembly. Standards listed: NFPA 252-2003, UL 10(b), UL 555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. MEA # 507-06-M Fire rated by Intertek – Warnock Hersey.

24″ x 24″ – Fire Rated Insulated Access Door with Flange – Stainless Steel

24
Check Price for 24

The PFI-SS access door is insulated with 2” thick mineral wool and can be used on fire rated walls and ceilings. It comes with a 1” flange for an easy flush installation on any type of surface. As per UL and NFPA standards, once the installation is complete and the provided springs are hooked to the back of the panel, the door will be self closing and self locking. The largest fire rated PFI doors available for vertical and horizontal installations with temperature rise are respectively: (48’’ x 48’’) and (24’’ x 36’’ or 864 sq inches). PFI-SS fire rated access door specifications,   Download Technical Data / Submittal Sheet (PFI-SS) Material: Stainless Steel #4 (Brushed Finish) Insulation: 2″ mineral wool Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat Packaging: Individually wrapped, 1 per box Fire Rating: For installation in vertical wall assemblies: Rating 1 1/2 hours. Temperature rise: 250°F (139°C) at 30 mins and 450°F (250°C) at 60 mins. Maximum door size of 48″ x 48″. Rating 3 hours. Temperature rise: 400°F at 60 mins. Maximum door size of 48″ x 48″. For installation in horizontal ceiling assemblies: With temperature rise: Rating 3 hours for non-cumbustible assembly and 1 hour for combustible assembly: Temperature rise: Max 250°F (139°C) at 30 mins, 450°F (250°C) at 60 mins. Maximum door size of 24″ x 36″ or 864 sq inches (see note 1) Without temperature rise: Rating: 3 hours for non-combustible assembly and 1 hour for combustible assembly. Standards listed: NFPA 252-2003, UL 10(b), UL 555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. MEA # 507-06-M Fire rated by Intertek – Warnock Hersey    LEED Certification:   The PFI access door can contribute directly to a project’s ability to achieve LEED certification: USA LEED-NC New Construction & Major Renovations LEED for Schools LEED-CI Commercial Interiors CANADA LEED Canada-NC New Construction & Major Renovations LEED Canada-CI Commercial Interiors Note 1: Maximum door size 24″ x 36″ can also be calculated by multiplying the surface area of the door (24″x36″). The maximum surface area is 864 sq inches. The maximum height or width is 36″. All door sizes equal or smaller than 864 sq inches fall within the standards. Ex. Door size of 28″ x 28″ = 784 sq inches..

24″ x 36″ – Fire Rated Insulated Access Door with Flange – Stainless Steel

24
Check Price for 24

The PFI-SS access door is insulated with 2” thick mineral wool and can be used on fire rated walls and ceilings. It comes with a 1” flange for an easy flush installation on any type of surface. As per UL and NFPA standards, once the installation is complete and the provided springs are hooked to the back of the panel, the door will be self closing and self locking. The largest fire rated PFI doors available for vertical and horizontal installations with temperature rise are respectively: (48’’ x 48’’) and (24’’ x 36’’ or 864 sq inches). PFI-SS fire rated access door specifications,   Download Technical Data / Submittal Sheet (PFI-SS) Material: Stainless Steel #4 (Brushed Finish) Insulation: 2″ mineral wool Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat Packaging: Individually wrapped, 1 per box Fire Rating: For installation in vertical wall assemblies: Rating 1 1/2 hours. Temperature rise: 250°F (139°C) at 30 mins and 450°F (250°C) at 60 mins. Maximum door size of 48″ x 48″. Rating 3 hours. Temperature rise: 400°F at 60 mins. Maximum door size of 48″ x 48″. For installation in horizontal ceiling assemblies: With temperature rise: Rating 3 hours for non-cumbustible assembly and 1 hour for combustible assembly: Temperature rise: Max 250°F (139°C) at 30 mins, 450°F (250°C) at 60 mins. Maximum door size of 24″ x 36″ or 864 sq inches (see note 1) Without temperature rise: Rating: 3 hours for non-combustible assembly and 1 hour for combustible assembly. Standards listed: NFPA 252-2003, UL 10(b), UL 555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. MEA # 507-06-M Fire rated by Intertek – Warnock Hersey    LEED Certification:   The PFI access door can contribute directly to a project’s ability to achieve LEED certification: USA LEED-NC New Construction & Major Renovations LEED for Schools LEED-CI Commercial Interiors CANADA LEED Canada-NC New Construction & Major Renovations LEED Canada-CI Commercial Interiors Note 1: Maximum door size 24″ x 36″ can also be calculated by multiplying the surface area of the door (24″x36″). The maximum surface area is 864 sq inches. The maximum height or width is 36″. All door sizes equal or smaller than 864 sq inches fall within the standards. Ex. Door size of 28″ x 28″ = 784 sq inches..

24″ x 48″ – Fire Rated Insulated Access Door with Flange – Stainless Steel

24
Check Price for 24

The PFI-SS access door is insulated with 2” thick mineral wool and can be used on fire rated walls and ceilings. It comes with a 1” flange for an easy flush installation on any type of surface. As per UL and NFPA standards, once the installation is complete and the provided springs are hooked to the back of the panel, the door will be self closing and self locking. The largest fire rated PFI doors available for vertical and horizontal installations with temperature rise are respectively: (48’’ x 48’’) and (24’’ x 36’’ or 864 sq inches). PFI-SS fire rated access door specifications,   Download Technical Data / Submittal Sheet (PFI-SS) Material: Stainless Steel #4 (Brushed Finish) Insulation: 2″ mineral wool Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat Packaging: Individually wrapped, 1 per box Fire Rating: For installation in vertical wall assemblies: Rating 1 1/2 hours. Temperature rise: 250°F (139°C) at 30 mins and 450°F (250°C) at 60 mins. Maximum door size of 48″ x 48″. Rating 3 hours. Temperature rise: 400°F at 60 mins. Maximum door size of 48″ x 48″. For installation in horizontal ceiling assemblies: With temperature rise: Rating 3 hours for non-cumbustible assembly and 1 hour for combustible assembly: Temperature rise: Max 250°F (139°C) at 30 mins, 450°F (250°C) at 60 mins. Maximum door size of 24″ x 36″ or 864 sq inches (see note 1) Without temperature rise: Rating: 3 hours for non-combustible assembly and 1 hour for combustible assembly. Standards listed: NFPA 252-2003, UL 10(b), UL 555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. MEA # 507-06-M Fire rated by Intertek – Warnock Hersey    LEED Certification:   The PFI access door can contribute directly to a project’s ability to achieve LEED certification: USA LEED-NC New Construction & Major Renovations LEED for Schools LEED-CI Commercial Interiors CANADA LEED Canada-NC New Construction & Major Renovations LEED Canada-CI Commercial Interiors Note 1: Maximum door size 24″ x 36″ can also be calculated by multiplying the surface area of the door (24″x36″). The maximum surface area is 864 sq inches. The maximum height or width is 36″. All door sizes equal or smaller than 864 sq inches fall within the standards. Ex. Door size of 28″ x 28″ = 784 sq inches..

30″ x 30″ – Fire Rated Insulated Access Door with Flange – Stainless Steel

30
Check Price for 30

The PFI-SS access door is insulated with 2” thick mineral wool and can be used on fire rated walls and ceilings. It comes with a 1” flange for an easy flush installation on any type of surface. As per UL and NFPA standards, once the installation is complete and the provided springs are hooked to the back of the panel, the door will be self closing and self locking. The largest fire rated PFI doors available for vertical and horizontal installations with temperature rise are respectively: (48’’ x 48’’) and (24’’ x 36’’ or 864 sq inches). PFI-SS fire rated access door specifications,   Download Technical Data / Submittal Sheet (PFI-SS) Material: Stainless Steel #4 (Brushed Finish) Insulation: 2″ mineral wool Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat Packaging: Individually wrapped, 1 per box Fire Rating: For installation in vertical wall assemblies: Rating 1 1/2 hours. Temperature rise: 250°F (139°C) at 30 mins and 450°F (250°C) at 60 mins. Maximum door size of 48″ x 48″. Rating 3 hours. Temperature rise: 400°F at 60 mins. Maximum door size of 48″ x 48″. For installation in horizontal ceiling assemblies: With temperature rise: Rating 3 hours for non-cumbustible assembly and 1 hour for combustible assembly: Temperature rise: Max 250°F (139°C) at 30 mins, 450°F (250°C) at 60 mins. Maximum door size of 24″ x 36″ or 864 sq inches (see note 1) Without temperature rise: Rating: 3 hours for non-combustible assembly and 1 hour for combustible assembly. Standards listed: NFPA 252-2003, UL 10(b), UL 555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. MEA # 507-06-M Fire rated by Intertek – Warnock Hersey    LEED Certification:   The PFI access door can contribute directly to a project’s ability to achieve LEED certification: USA LEED-NC New Construction & Major Renovations LEED for Schools LEED-CI Commercial Interiors CANADA LEED Canada-NC New Construction & Major Renovations LEED Canada-CI Commercial Interiors Note 1: Maximum door size 24″ x 36″ can also be calculated by multiplying the surface area of the door (24″x36″). The maximum surface area is 864 sq inches. The maximum height or width is 36″. All door sizes equal or smaller than 864 sq inches fall within the standards. Ex. Door size of 28″ x 28″ = 784 sq inches..

32″ x 32″ – Fire Rated Insulated Access Door with Flange – Stainless Steel

32
Check Price for 32

The PFI-SS access door is insulated with 2” thick mineral wool and can be used on fire rated walls and ceilings. It comes with a 1” flange for an easy flush installation on any type of surface. As per UL and NFPA standards, once the installation is complete and the provided springs are hooked to the back of the panel, the door will be self closing and self locking. The largest fire rated PFI doors available for vertical and horizontal installations with temperature rise are respectively: (48’’ x 48’’) and (24’’ x 36’’ or 864 sq inches). PFI-SS fire rated access door specifications,   Download Technical Data / Submittal Sheet (PFI-SS) Material: Stainless Steel #4 (Brushed Finish) Insulation: 2″ mineral wool Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat Packaging: Individually wrapped, 1 per box Fire Rating: For installation in vertical wall assemblies: Rating 1 1/2 hours. Temperature rise: 250°F (139°C) at 30 mins and 450°F (250°C) at 60 mins. Maximum door size of 48″ x 48″. Rating 3 hours. Temperature rise: 400°F at 60 mins. Maximum door size of 48″ x 48″. For installation in horizontal ceiling assemblies: With temperature rise: Rating 3 hours for non-cumbustible assembly and 1 hour for combustible assembly: Temperature rise: Max 250°F (139°C) at 30 mins, 450°F (250°C) at 60 mins. Maximum door size of 24″ x 36″ or 864 sq inches (see note 1) Without temperature rise: Rating: 3 hours for non-combustible assembly and 1 hour for combustible assembly. Standards listed: NFPA 252-2003, UL 10(b), UL 555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. MEA # 507-06-M Fire rated by Intertek – Warnock Hersey    LEED Certification:   The PFI access door can contribute directly to a project’s ability to achieve LEED certification: USA LEED-NC New Construction & Major Renovations LEED for Schools LEED-CI Commercial Interiors CANADA LEED Canada-NC New Construction & Major Renovations LEED Canada-CI Commercial Interiors Note 1: Maximum door size 24″ x 36″ can also be calculated by multiplying the surface area of the door (24″x36″). The maximum surface area is 864 sq inches. The maximum height or width is 36″. All door sizes equal or smaller than 864 sq inches fall within the standards. Ex. Door size of 28″ x 28″ = 784 sq inches..

36″ x 36″ – Fire Rated Insulated Access Door with Flange – Stainless Steel

36
Check Price for 36

The PFI-SS access door is insulated with 2” thick mineral wool and can be used on fire rated walls and ceilings. It comes with a 1” flange for an easy flush installation on any type of surface. As per UL and NFPA standards, once the installation is complete and the provided springs are hooked to the back of the panel, the door will be self closing and self locking. The largest fire rated PFI doors available for vertical and horizontal installations with temperature rise are respectively: (48’’ x 48’’) and (24’’ x 36’’ or 864 sq inches). PFI-SS fire rated access door specifications,   Download Technical Data / Submittal Sheet (PFI-SS) Material: Stainless Steel #4 (Brushed Finish) Insulation: 2″ mineral wool Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat Packaging: Individually wrapped, 1 per box Fire Rating: For installation in vertical wall assemblies: Rating 1 1/2 hours. Temperature rise: 250°F (139°C) at 30 mins and 450°F (250°C) at 60 mins. Maximum door size of 48″ x 48″. Rating 3 hours. Temperature rise: 400°F at 60 mins. Maximum door size of 48″ x 48″. For installation in horizontal ceiling assemblies: With temperature rise: Rating 3 hours for non-cumbustible assembly and 1 hour for combustible assembly: Temperature rise: Max 250°F (139°C) at 30 mins, 450°F (250°C) at 60 mins. Maximum door size of 24″ x 36″ or 864 sq inches (see note 1) Without temperature rise: Rating: 3 hours for non-combustible assembly and 1 hour for combustible assembly. Standards listed: NFPA 252-2003, UL 10(b), UL 555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. MEA # 507-06-M Fire rated by Intertek – Warnock Hersey    LEED Certification:   The PFI access door can contribute directly to a project’s ability to achieve LEED certification: USA LEED-NC New Construction & Major Renovations LEED for Schools LEED-CI Commercial Interiors CANADA LEED Canada-NC New Construction & Major Renovations LEED Canada-CI Commercial Interiors Note 1: Maximum door size 24″ x 36″ can also be calculated by multiplying the surface area of the door (24″x36″). The maximum surface area is 864 sq inches. The maximum height or width is 36″. All door sizes equal or smaller than 864 sq inches fall within the standards. Ex. Door size of 28″ x 28″ = 784 sq inches..

48″ x 48″ – Fire Rated Insulated Access Door with Flange – Stainless Steel

48
Check Price for 48

The PFI-SS access door is insulated with 2” thick mineral wool and can be used on fire rated walls and ceilings. It comes with a 1” flange for an easy flush installation on any type of surface. As per UL and NFPA standards, once the installation is complete and the provided springs are hooked to the back of the panel, the door will be self closing and self locking. The largest fire rated PFI doors available for vertical and horizontal installations with temperature rise are respectively: (48’’ x 48’’) and (24’’ x 36’’ or 864 sq inches). PFI-SS fire rated access door specifications,   Download Technical Data / Submittal Sheet (PFI-SS) Material: Stainless Steel #4 (Brushed Finish) Insulation: 2″ mineral wool Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat Packaging: Individually wrapped, 1 per box Fire Rating: For installation in vertical wall assemblies: Rating 1 1/2 hours. Temperature rise: 250°F (139°C) at 30 mins and 450°F (250°C) at 60 mins. Maximum door size of 48″ x 48″. Rating 3 hours. Temperature rise: 400°F at 60 mins. Maximum door size of 48″ x 48″. For installation in horizontal ceiling assemblies: With temperature rise: Rating 3 hours for non-cumbustible assembly and 1 hour for combustible assembly: Temperature rise: Max 250°F (139°C) at 30 mins, 450°F (250°C) at 60 mins. Maximum door size of 24″ x 36″ or 864 sq inches (see note 1) Without temperature rise: Rating: 3 hours for non-combustible assembly and 1 hour for combustible assembly. Standards listed: NFPA 252-2003, UL 10(b), UL 555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. MEA # 507-06-M Fire rated by Intertek – Warnock Hersey    LEED Certification:   The PFI access door can contribute directly to a project’s ability to achieve LEED certification: USA LEED-NC New Construction & Major Renovations LEED for Schools LEED-CI Commercial Interiors CANADA LEED Canada-NC New Construction & Major Renovations LEED Canada-CI Commercial Interiors Note 1: Maximum door size 24″ x 36″ can also be calculated by multiplying the surface area of the door (24″x36″). The maximum surface area is 864 sq inches. The maximum height or width is 36″. All door sizes equal or smaller than 864 sq inches fall within the standards. Ex. Door size of 28″ x 28″ = 784 sq inches..

12″ x 12″ Fire Rated Un-Insulated Recessed Door for Drywall – BEST

12
Check Price for 12

12″ x 12″ Fire Rated Un-Insulated Recessed Door for Drywall Walls The BA-FB-5015 recessed for drywall, fire rated access door is designed for installation in drywall walls requiring concealing of the door panel consistent to the surrounding walls. The door panel is supplied with 5/8″ drywall. The Acudor FB-5015 is approved by Underwriter’s Laboratories (UL) for 1-1/2 hours “B” label in walls. Designed to maintain continuity in a 2 hour fire barrier wall, the BA-FB-5015 should be used whenever it is necessary to provide access in fire rated drywall walls, where it is required to conceal the door panel. – Application: – For installation in drywall walls requiring concealing of the door panel consistent to surrounding walls- Designed for openings that require a 1 1/2 hour fire rating when temperature rise is not a factor. Product Features – Recessed reinforced door fitted with 5/8″ drywall (supplied with door).- Concealed hinge, Self-closing, Self-latching- Inside latch release- Frame flange with pre-punched holes and textured for convenient mounting and accepting skim coat finish. BA-FB-5015 Access Door Specifications: – Door: Steel-22 Gauge recessed fitted with 5/8″ thick drywall suitable to accept skim coat finish on site- Door Frame: Steel-22 Gauge press bent for strength and rigidity with pre-punched flanges for convenient mounting and accepting skim coat finish on site- Hinge: Concealed- Fire Rating (Walls): Meets 11/2 hour fire rating requirement in accordance with Underwriters Laboratories UL 10(b) and CAN/ULC S104-10 for max size upto 24″ x 36″- Latch: Self-latching bolt, operated by flush key- Finish: Satin coat steel.