Category: Fire-Rated Doors

14″ x 14″ – Fire Rated Insulated Access Door with Flange – Stainless Steel

14
Check Price for 14

The PFI-SS access door is insulated with 2” thick mineral wool and can be used on fire rated walls and ceilings. It comes with a 1” flange for an easy flush installation on any type of surface. As per UL and NFPA standards, once the installation is complete and the provided springs are hooked to the back of the panel, the door will be self closing and self locking. The largest fire rated PFI doors available for vertical and horizontal installations with temperature rise are respectively: (48’’ x 48’’) and (24’’ x 36’’ or 864 sq inches). PFI-SS fire rated access door specifications,   Download Technical Data / Submittal Sheet (PFI-SS) Material: Stainless Steel #4 (Brushed Finish) Insulation: 2″ mineral wool Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat Packaging: Individually wrapped, 1 per box Fire Rating: For installation in vertical wall assemblies: Rating 1 1/2 hours. Temperature rise: 250°F (139°C) at 30 mins and 450°F (250°C) at 60 mins. Maximum door size of 48″ x 48″. Rating 3 hours. Temperature rise: 400°F at 60 mins. Maximum door size of 48″ x 48″. For installation in horizontal ceiling assemblies: With temperature rise: Rating 3 hours for non-cumbustible assembly and 1 hour for combustible assembly: Temperature rise: Max 250°F (139°C) at 30 mins, 450°F (250°C) at 60 mins. Maximum door size of 24″ x 36″ or 864 sq inches (see note 1) Without temperature rise: Rating: 3 hours for non-combustible assembly and 1 hour for combustible assembly. Standards listed: NFPA 252-2003, UL 10(b), UL 555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. MEA # 507-06-M Fire rated by Intertek – Warnock Hersey    LEED Certification:   The PFI access door can contribute directly to a project’s ability to achieve LEED certification: USA LEED-NC New Construction & Major Renovations LEED for Schools LEED-CI Commercial Interiors CANADA LEED Canada-NC New Construction & Major Renovations LEED Canada-CI Commercial Interiors Note 1: Maximum door size 24″ x 36″ can also be calculated by multiplying the surface area of the door (24″x36″). The maximum surface area is 864 sq inches. The maximum height or width is 36″. All door sizes equal or smaller than 864 sq inches fall within the standards. Ex. Door size of 28″ x 28″ = 784 sq inches..

18″ x 18″ Fire Rated Insulated Access Door with Flange – BEST

18
Check Price for 18

18″ x 18″ Fire Rated Insulated Recessed Door with Flange The BA-FW-5050 is an insulated, fire rated access door approved for use in walls and ceilings. For walls, this door has an Underwriters Laboratories (UL and ULC), 1-1/2 hour “B” label, with a maximum temperature rise of 250 degrees after 30 minutes. This door should be used in walls when temperature rise or heat transmission is a factor. For fire rated ceilings, this door has been approved by Warnock Hersey International for 3 hours (max. size to 24″ x 36″) – Application: – For all types of walls and ceilings- This door should be used in walls when temperature rise or heat transmission is a factor. Product Features – Insulated door panel – Concealed hinge – Self-closing – Self-Latching- Inside latch release BA-FB-5050 Access Door Specifications: – Door / Door Frame: Steel 20 gage door,16 gage mounting frame Door filled with 2″ thick fire rated insulation, flange to be 1″ wideHinge: Concealed- Fire Rating (Walls): UL — 1-1/2 hour “B” label. ULC — 2 hour “B” label Max size: 36 x 48. (Ceilings): Warnock Hersey International 3 hour rated in a non-combustible ceiling. 1 hour rated in a combustible ceiling. Max size: 24 x 36 – Standard Latch: Universal self-latching bolt, operated by either a knurled knob or flush key. When master keying is required, doors can be prepared for mortise cylinder locks.- Finish: Steel: 5 stage iron phosphate preparation with prime coat of white baked-on enamel.

16″ x 16″ Fire Rated Insulated Access Door with Flange – BEST

16
Check Price for 16

16″ x 16″ Fire Rated Insulated Recessed Door with Flange The BA-FW-5050 is an insulated, fire rated access door approved for use in walls and ceilings. For walls, this door has an Underwriters Laboratories (UL and ULC), 1-1/2 hour “B” label, with a maximum temperature rise of 250 degrees after 30 minutes. This door should be used in walls when temperature rise or heat transmission is a factor. For fire rated ceilings, this door has been approved by Warnock Hersey International for 3 hours (max. size to 24″ x 36″) – Application: – For all types of walls and ceilings- This door should be used in walls when temperature rise or heat transmission is a factor. Product Features – Insulated door panel – Concealed hinge – Self-closing – Self-Latching- Inside latch release BA-FB-5050 Access Door Specifications: – Door / Door Frame: Steel 20 gage door,16 gage mounting frame Door filled with 2″ thick fire rated insulation, flange to be 1″ wideHinge: Concealed- Fire Rating (Walls): UL — 1-1/2 hour “B” label. ULC — 2 hour “B” label Max size: 36 x 48. (Ceilings): Warnock Hersey International 3 hour rated in a non-combustible ceiling. 1 hour rated in a combustible ceiling. Max size: 24 x 36 – Standard Latch: Universal self-latching bolt, operated by either a knurled knob or flush key. When master keying is required, doors can be prepared for mortise cylinder locks.- Finish: Steel: 5 stage iron phosphate preparation with prime coat of white baked-on enamel.

24″ x 24″ Fire Rated Un-Insulated Access Door with Flange – BEST

24
Check Price for 24

24″ x 24″ Fire Rated Un-Insulated Access Door with Flange Approved by Underwriters Laboratories (UL) for 1 ½ hours “B” label in walls and ULC for 2 hours “B” label in walls. Designed to maintain continuity in a 2-hour fire barrier wall, the FB-5060 should be used whenever it is necessary to provide access in fire rated walls, when temperature rise is not a factor.   In-Stock and Ready to Ship !     Download Technical Data / Submittal Sheet (BA-FB-5060)   Application: • Designed to provide access in walls, while maintaining an invisible, architecturally pleasing appearance Product Features   Product Features • Concealed hinge • Self-closing • Self-Latching• Inside latch release  BA-FB-5060 Access Door Specifications: Door / Door Frame: Steel 16 gage door, 16 gage mounting frame. Flush to frame with reinforced edges, flange to be 1″ wideHinge: ConcealedFire Rating (Walls): UL — 1-1/2 hour “B” label. ULC — 2 hour “B” label. (optional)Max size 36 x 48Standard Latch: Universal self-latching bolt, operated by either a knurled knob or flush key. When master keying is required, doors can be prepared for rim or mortise cylinder locks.Finish: Steel: 5 stage iron phosphate preparation with prime coat of White alkyd baked-on enamel. Â.

14″ x 14″ Fire Rated Insulated Access Door with Flange – BEST

14
Check Price for 14

14″ x 14″ Fire Rated Insulated Recessed Door with Flange The BA-FW-5050 is an insulated, fire rated access door approved for use in walls and ceilings. For walls, this door has an Underwriters Laboratories (UL and ULC), 1-1/2 hour “B” label, with a maximum temperature rise of 250 degrees after 30 minutes. This door should be used in walls when temperature rise or heat transmission is a factor. For fire rated ceilings, this door has been approved by Warnock Hersey International for 3 hours (max. size to 24″ x 36″) – Application: – For all types of walls and ceilings- This door should be used in walls when temperature rise or heat transmission is a factor. Product Features – Insulated door panel – Concealed hinge – Self-closing – Self-Latching- Inside latch release BA-FB-5050 Access Door Specifications: – Door / Door Frame: Steel 20 gage door,16 gage mounting frame Door filled with 2″ thick fire rated insulation, flange to be 1″ wideHinge: Concealed- Fire Rating (Walls): UL — 1-1/2 hour “B” label. ULC — 2 hour “B” label Max size: 36 x 48. (Ceilings): Warnock Hersey International 3 hour rated in a non-combustible ceiling. 1 hour rated in a combustible ceiling. Max size: 24 x 36 – Standard Latch: Universal self-latching bolt, operated by either a knurled knob or flush key. When master keying is required, doors can be prepared for mortise cylinder locks.- Finish: Steel: 5 stage iron phosphate preparation with prime coat of white baked-on enamel.

7″ x 7″ Grease Duct Access Panel – BEST

7
Check Price for 7

7″ x 7″ Grease Duct Access Panel The BA-GDD is a UL and ULC listed access door for installation into grease ducts. The 16 gage steel construction along with the high temperature resistant gasket and sealant allows this door to be grease tight and airtight. This door meets or exceeds requirements of all mechanical codes. – Application – Access door for installation in Kitchen Exhaust Systems- This door meets or exceeds requirements of all mechanical codes Product Features – Bolt in unit easily installed into existing ductwork- Duct cutout template included- No bolts penetrate to the interior of the duct- Two handles for easy removal and installation- 16 Gage galvanized steel- N.F.P.A. #96.

Rated Access Doors BA-PFN-GYP Fire Rated Drywall Access Panel with Flange 36″ x 36″ – BEST

Rated Access Doors BA-PFN-GYP Fire Rated Drywall Access Panel with Flange 36
Check Price for Rated Access Doors BA-PFN-GYP Fire Rated Drywall Access Panel with Flange 36

36″ x 36″ – Fire Rated Un-Insulated Access Door with Drywall Flange . BA-PFN-GYP access Hatch is not insulated and can only be used on fire rated walls, specifically those made of drywall. Once a sufficient layer of drywall compound is applied to its corner bead flange it will leave only the door panel visible for a much better finished look. As per UL standards, once the installation is complete and the provided springs installed, this access door will be self closing and self locking. It should not be used in situations where protection against temperature elevation is required. The largest fire rated PFN-GYP door available is: (36″ x 36″ ).BA-PFN-GYP fire rated access door specifications, Submittal Sheet – Material: 16 gauge cold rolled steel frame and 20 gauge galvanneal steel door Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat . For installation in vertical wall assemblies 2 hour fire barrier, rating 1 frac12 hours. Access/Door Frame Assembly (uninsulated) for installation in vertical wall assemblies. Standards listed: NFPA 252-2003, UL 10b, UL-555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. /h3> MEA # 507-06-M /h3> Fire rated by Intertek – Warnock Hersey.

Fire Rated Access Panels BA-PFN-PLY 8 x 8 Drywall Access Panel with Flange – BEST

Fire Rated Access Panels BA-PFN-PLY 8 x 8 Drywall Access Panel with Flange - BEST
Check Price for Fire Rated Access Panels BA-PFN-PLY 8 x 8 Drywall Access Panel with Flange - BEST

The BA-PFN-PLY access door is not insulated and can only be used on fire rated walls, specifically those made of plaster. Once covered with plaster, the 2 3/4″ lath flange will disappear, leaving only the door panel visible. As per UL standards, once the installation is complete and the provided springs installed, this door will be self closing and self locking. It should not be used in situations where protection against temperature elevation is required. The largest fire rated PFN-PLY door available is: (36″ x 36″). BA-PFN-PLY fire rated access door specifications, – Material: 16 gauge cold rolled steel frame and 20 gauge galvanneal steel door Insulation: 2″ mineral wool Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat Packaging: Individually wrapped, 1 per box Fire Rating: For installation in vertical wall assemblies 2 hour fire barrier, rating 11/2 hours. Access/Door Frame Assembly (uninsulated) for installation in vertical wall assemblies. Maximum door size of: 36″ x 36″. Standards listed: NFPA 252-2003, UL 10b, UL-555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. : MEA # 507-06-M Fire rated by Intertek – Warnock Hersey LEED Certification: This access door can contribute directly to a project’s ability to achieve LEED certification: USA LEED-NC New Construction & Major Renovations LEED for Schools LEED-CI Commercial Interiors CANADA LEED Canada-NC New Construction & Major Renovations LEED Canada-CI Commercial Interiors.

10″ x 10″ Fire Rated Insulated Access Door with Flange – BEST

10
Check Price for 10

10″ x 10″ Fire Rated Insulated Recessed Door with Flange The BA-FW-5050 is an insulated, fire rated access door approved for use in walls and ceilings. For walls, this door has an Underwriters Laboratories (UL and ULC), 1-1/2 hour “B” label, with a maximum temperature rise of 250 degrees after 30 minutes. This door should be used in walls when temperature rise or heat transmission is a factor. For fire rated ceilings, this door has been approved by Warnock Hersey International for 3 hours (max. size to 24″ x 36″) – Application: – For all types of walls and ceilings- This door should be used in walls when temperature rise or heat transmission is a factor. Product Features – Insulated door panel – Concealed hinge – Self-closing – Self-Latching- Inside latch release BA-FB-5050 Access Door Specifications: – Door / Door Frame: Steel 20 gage door,16 gage mounting frame Door filled with 2″ thick fire rated insulation, flange to be 1″ wideHinge: Concealed- Fire Rating (Walls): UL — 1-1/2 hour “B” label. ULC — 2 hour “B” label Max size: 36 x 48. (Ceilings): Warnock Hersey International 3 hour rated in a non-combustible ceiling. 1 hour rated in a combustible ceiling. Max size: 24 x 36 – Standard Latch: Universal self-latching bolt, operated by either a knurled knob or flush key. When master keying is required, doors can be prepared for mortise cylinder locks.- Finish: Steel: 5 stage iron phosphate preparation with prime coat of white baked-on enamel.

12″ x 12″ Fire Rated Insulated Access Door with Flange – BEST

12
Check Price for 12

12″ x 12″ Fire Rated Insulated Recessed Door with Flange The BA-FW-5050 is an insulated, fire rated access door approved for use in walls and ceilings. For walls, this door has an Underwriters Laboratories (UL and ULC), 1-1/2 hour “B” label, with a maximum temperature rise of 250 degrees after 30 minutes. This door should be used in walls when temperature rise or heat transmission is a factor. For fire rated ceilings, this door has been approved by Warnock Hersey International for 3 hours (max. size to 24″ x 36″) – Application: – For all types of walls and ceilings- This door should be used in walls when temperature rise or heat transmission is a factor. Product Features – Insulated door panel – Concealed hinge – Self-closing – Self-Latching- Inside latch release BA-FB-5050 Access Door Specifications: – Door / Door Frame: Steel 20 gage door,16 gage mounting frame Door filled with 2″ thick fire rated insulation, flange to be 1″ wideHinge: Concealed- Fire Rating (Walls): UL — 1-1/2 hour “B” label. ULC — 2 hour “B” label Max size: 36 x 48. (Ceilings): Warnock Hersey International 3 hour rated in a non-combustible ceiling. 1 hour rated in a combustible ceiling. Max size: 24 x 36 – Standard Latch: Universal self-latching bolt, operated by either a knurled knob or flush key. When master keying is required, doors can be prepared for mortise cylinder locks.- Finish: Steel: 5 stage iron phosphate preparation with prime coat of white baked-on enamel.

Recent Entries »