18″ x 18″ – Fire Rated Insulated Access Door with Flange – Stainless Steel

18
Check Price for 18

The PFI-SS access door is insulated with 2” thick mineral wool and can be used on fire rated walls and ceilings. It comes with a 1” flange for an easy flush installation on any type of surface. As per UL and NFPA standards, once the installation is complete and the provided springs are hooked to the back of the panel, the door will be self closing and self locking. The largest fire rated PFI doors available for vertical and horizontal installations with temperature rise are respectively: (48’’ x 48’’) and (24’’ x 36’’ or 864 sq inches). PFI-SS fire rated access door specifications,   Download Technical Data / Submittal Sheet (PFI-SS) Material: Stainless Steel #4 (Brushed Finish) Insulation: 2″ mineral wool Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat Packaging: Individually wrapped, 1 per box Fire Rating: For installation in vertical wall assemblies: Rating 1 1/2 hours. Temperature rise: 250°F (139°C) at 30 mins and 450°F (250°C) at 60 mins. Maximum door size of 48″ x 48″. Rating 3 hours. Temperature rise: 400°F at 60 mins. Maximum door size of 48″ x 48″. For installation in horizontal ceiling assemblies: With temperature rise: Rating 3 hours for non-cumbustible assembly and 1 hour for combustible assembly: Temperature rise: Max 250°F (139°C) at 30 mins, 450°F (250°C) at 60 mins. Maximum door size of 24″ x 36″ or 864 sq inches (see note 1) Without temperature rise: Rating: 3 hours for non-combustible assembly and 1 hour for combustible assembly. Standards listed: NFPA 252-2003, UL 10(b), UL 555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. MEA # 507-06-M Fire rated by Intertek – Warnock Hersey    LEED Certification:   The PFI access door can contribute directly to a project’s ability to achieve LEED certification: USA LEED-NC New Construction & Major Renovations LEED for Schools LEED-CI Commercial Interiors CANADA LEED Canada-NC New Construction & Major Renovations LEED Canada-CI Commercial Interiors Note 1: Maximum door size 24″ x 36″ can also be calculated by multiplying the surface area of the door (24″x36″). The maximum surface area is 864 sq inches. The maximum height or width is 36″. All door sizes equal or smaller than 864 sq inches fall within the standards. Ex. Door size of 28″ x 28″ = 784 sq inches..

16″ x 16″ – Fire Rated Insulated Access Door with Flange – Stainless Steel

16
Check Price for 16

The PFI-SS access door is insulated with 2” thick mineral wool and can be used on fire rated walls and ceilings. It comes with a 1” flange for an easy flush installation on any type of surface. As per UL and NFPA standards, once the installation is complete and the provided springs are hooked to the back of the panel, the door will be self closing and self locking. The largest fire rated PFI doors available for vertical and horizontal installations with temperature rise are respectively: (48’’ x 48’’) and (24’’ x 36’’ or 864 sq inches). PFI-SS fire rated access door specifications,   Download Technical Data / Submittal Sheet (PFI-SS) Material: Stainless Steel #4 (Brushed Finish) Insulation: 2″ mineral wool Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat Packaging: Individually wrapped, 1 per box Fire Rating: For installation in vertical wall assemblies: Rating 1 1/2 hours. Temperature rise: 250°F (139°C) at 30 mins and 450°F (250°C) at 60 mins. Maximum door size of 48″ x 48″. Rating 3 hours. Temperature rise: 400°F at 60 mins. Maximum door size of 48″ x 48″. For installation in horizontal ceiling assemblies: With temperature rise: Rating 3 hours for non-cumbustible assembly and 1 hour for combustible assembly: Temperature rise: Max 250°F (139°C) at 30 mins, 450°F (250°C) at 60 mins. Maximum door size of 24″ x 36″ or 864 sq inches (see note 1) Without temperature rise: Rating: 3 hours for non-combustible assembly and 1 hour for combustible assembly. Standards listed: NFPA 252-2003, UL 10(b), UL 555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. MEA # 507-06-M Fire rated by Intertek – Warnock Hersey    LEED Certification:   The PFI access door can contribute directly to a project’s ability to achieve LEED certification: USA LEED-NC New Construction & Major Renovations LEED for Schools LEED-CI Commercial Interiors CANADA LEED Canada-NC New Construction & Major Renovations LEED Canada-CI Commercial Interiors Note 1: Maximum door size 24″ x 36″ can also be calculated by multiplying the surface area of the door (24″x36″). The maximum surface area is 864 sq inches. The maximum height or width is 36″. All door sizes equal or smaller than 864 sq inches fall within the standards. Ex. Door size of 28″ x 28″ = 784 sq inches..

14″ x 14″ – Fire Rated Insulated Access Door with Flange – Stainless Steel

14
Check Price for 14

The PFI-SS access door is insulated with 2” thick mineral wool and can be used on fire rated walls and ceilings. It comes with a 1” flange for an easy flush installation on any type of surface. As per UL and NFPA standards, once the installation is complete and the provided springs are hooked to the back of the panel, the door will be self closing and self locking. The largest fire rated PFI doors available for vertical and horizontal installations with temperature rise are respectively: (48’’ x 48’’) and (24’’ x 36’’ or 864 sq inches). PFI-SS fire rated access door specifications,   Download Technical Data / Submittal Sheet (PFI-SS) Material: Stainless Steel #4 (Brushed Finish) Insulation: 2″ mineral wool Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat Packaging: Individually wrapped, 1 per box Fire Rating: For installation in vertical wall assemblies: Rating 1 1/2 hours. Temperature rise: 250°F (139°C) at 30 mins and 450°F (250°C) at 60 mins. Maximum door size of 48″ x 48″. Rating 3 hours. Temperature rise: 400°F at 60 mins. Maximum door size of 48″ x 48″. For installation in horizontal ceiling assemblies: With temperature rise: Rating 3 hours for non-cumbustible assembly and 1 hour for combustible assembly: Temperature rise: Max 250°F (139°C) at 30 mins, 450°F (250°C) at 60 mins. Maximum door size of 24″ x 36″ or 864 sq inches (see note 1) Without temperature rise: Rating: 3 hours for non-combustible assembly and 1 hour for combustible assembly. Standards listed: NFPA 252-2003, UL 10(b), UL 555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. MEA # 507-06-M Fire rated by Intertek – Warnock Hersey    LEED Certification:   The PFI access door can contribute directly to a project’s ability to achieve LEED certification: USA LEED-NC New Construction & Major Renovations LEED for Schools LEED-CI Commercial Interiors CANADA LEED Canada-NC New Construction & Major Renovations LEED Canada-CI Commercial Interiors Note 1: Maximum door size 24″ x 36″ can also be calculated by multiplying the surface area of the door (24″x36″). The maximum surface area is 864 sq inches. The maximum height or width is 36″. All door sizes equal or smaller than 864 sq inches fall within the standards. Ex. Door size of 28″ x 28″ = 784 sq inches..

12″ x 12″ – Fire Rated Insulated Access Door with Flange – Stainless Steel

12
Check Price for 12

The PFI-SS access door is insulated with 2” thick mineral wool and can be used on fire rated walls and ceilings. It comes with a 1” flange for an easy flush installation on any type of surface. As per UL and NFPA standards, once the installation is complete and the provided springs are hooked to the back of the panel, the door will be self closing and self locking. The largest fire rated PFI doors available for vertical and horizontal installations with temperature rise are respectively: (48’’ x 48’’) and (24’’ x 36’’ or 864 sq inches). PFI-SS fire rated access door specifications,   Download Technical Data / Submittal Sheet (PFI-SS) Material: Stainless Steel #4 (Brushed Finish) Insulation: 2″ mineral wool Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat Packaging: Individually wrapped, 1 per box Fire Rating: For installation in vertical wall assemblies: Rating 1 1/2 hours. Temperature rise: 250°F (139°C) at 30 mins and 450°F (250°C) at 60 mins. Maximum door size of 48″ x 48″. Rating 3 hours. Temperature rise: 400°F at 60 mins. Maximum door size of 48″ x 48″. For installation in horizontal ceiling assemblies: With temperature rise: Rating 3 hours for non-cumbustible assembly and 1 hour for combustible assembly: Temperature rise: Max 250°F (139°C) at 30 mins, 450°F (250°C) at 60 mins. Maximum door size of 24″ x 36″ or 864 sq inches (see note 1) Without temperature rise: Rating: 3 hours for non-combustible assembly and 1 hour for combustible assembly. Standards listed: NFPA 252-2003, UL 10(b), UL 555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. MEA # 507-06-M Fire rated by Intertek – Warnock Hersey    LEED Certification:   The PFI access door can contribute directly to a project’s ability to achieve LEED certification: USA LEED-NC New Construction & Major Renovations LEED for Schools LEED-CI Commercial Interiors CANADA LEED Canada-NC New Construction & Major Renovations LEED Canada-CI Commercial Interiors Note 1: Maximum door size 24″ x 36″ can also be calculated by multiplying the surface area of the door (24″x36″). The maximum surface area is 864 sq inches. The maximum height or width is 36″. All door sizes equal or smaller than 864 sq inches fall within the standards. Ex. Door size of 28″ x 28″ = 784 sq inches..

10″ x 10″ – Fire Rated Insulated Access Door with Flange – Stainless Steel

10
Check Price for 10

The PFI-SS access door is insulated with 2” thick mineral wool and can be used on fire rated walls and ceilings. It comes with a 1” flange for an easy flush installation on any type of surface. As per UL and NFPA standards, once the installation is complete and the provided springs are hooked to the back of the panel, the door will be self closing and self locking. The largest fire rated PFI doors available for vertical and horizontal installations with temperature rise are respectively: (48’’ x 48’’) and (24’’ x 36’’ or 864 sq inches). PFI-SS fire rated access door specifications,   Download Technical Data / Submittal Sheet (PFI-SS) Material: Stainless Steel #4 (Brushed Finish) Insulation: 2″ mineral wool Hinge: Continuous piano hinge Lock / latch: Self latching tool-key operated slam latch and/or ring operated slam latch, both included Inside panel release: Included on all slam latch fire doors Automatic panel closer: Standard on all doors Finish: DuPont high quality white powder coat Packaging: Individually wrapped, 1 per box Fire Rating: For installation in vertical wall assemblies: Rating 1 1/2 hours. Temperature rise: 250°F (139°C) at 30 mins and 450°F (250°C) at 60 mins. Maximum door size of 48″ x 48″. Rating 3 hours. Temperature rise: 400°F at 60 mins. Maximum door size of 48″ x 48″. For installation in horizontal ceiling assemblies: With temperature rise: Rating 3 hours for non-cumbustible assembly and 1 hour for combustible assembly: Temperature rise: Max 250°F (139°C) at 30 mins, 450°F (250°C) at 60 mins. Maximum door size of 24″ x 36″ or 864 sq inches (see note 1) Without temperature rise: Rating: 3 hours for non-combustible assembly and 1 hour for combustible assembly. Standards listed: NFPA 252-2003, UL 10(b), UL 555, CAN/ULC S112 M90-R2001, CAN/ULC S104-10. MEA # 507-06-M Fire rated by Intertek – Warnock Hersey    LEED Certification:   The PFI access door can contribute directly to a project’s ability to achieve LEED certification: USA LEED-NC New Construction & Major Renovations LEED for Schools LEED-CI Commercial Interiors CANADA LEED Canada-NC New Construction & Major Renovations LEED Canada-CI Commercial Interiors Note 1: Maximum door size 24″ x 36″ can also be calculated by multiplying the surface area of the door (24″x36″). The maximum surface area is 864 sq inches. The maximum height or width is 36″. All door sizes equal or smaller than 864 sq inches fall within the standards. Ex. Door size of 28″ x 28″ = 784 sq inches..

24″ x 36″ Sound Rated Access Panel – STC Series

24
Check Price for 24

24″ x 36″ Sound – Rated Access Panel STC – JL Industries Introduces the First STC-Rated Access Panel with an STC 47 Rating Meet Noise Containment and Sound Transmission Blocking Requirements for Walls with the US Patent Pending STC Panel Rated by Intertek Warnock Hersey http://www.bestaccessdoors.com/content/specs/STC.pdf Technical Data Submittal Sheet (STC) HIPAA Requirements for Patient Privacy LEED Enhanced Acoustical Performance Credits for Schools Proper Installation is Critical to Create the STC-Rated Sound Barrier. For best results, Activatar Construction Products Group, Inc. (ACPG) Recommends the use of Green Glue Acoustic Sealant as manufactured by Saint-Gobain Company..

24″ x 24″ Sound Rated Access Panel – STC Series

24
Check Price for 24

24″ x 24″ Sound – Rated Access Panel STC – JL Industries Introduces the First STC-Rated Access Panel with an STC 47 Rating Meet Noise Containment and Sound Transmission Blocking Requirements for Walls with the US Patent Pending STC Panel Rated by Intertek Warnock Hersey http://www.bestaccessdoors.com/content/specs/STC.pdf Technical Data Submittal Sheet (STC) HIPAA Requirements for Patient Privacy LEED Enhanced Acoustical Performance Credits for Schools Proper Installation is Critical to Create the STC-Rated Sound Barrier. For best results, Activatar Construction Products Group, Inc. (ACPG) Recommends the use of Green Glue Acoustic Sealant as manufactured by Saint-Gobain Company..

18″ x 18″ Sound Rated Access Panel – STC Series

18
Check Price for 18

18″ x 18″ Sound – Rated Access Panel STC – JL Industries Introduces the First STC-Rated Access Panel with an STC 47 Rating Meet Noise Containment and Sound Transmission Blocking Requirements for Walls with the US Patent Pending STC Panel Rated by Intertek Warnock Hersey http://www.bestaccessdoors.com/content/specs/STC.pdf Technical Data Submittal Sheet (STC) HIPAA Requirements for Patient Privacy LEED Enhanced Acoustical Performance Credits for Schools Proper Installation is Critical to Create the STC-Rated Sound Barrier. For best results, Activatar Construction Products Group, Inc. (ACPG) Recommends the use of Green Glue Acoustic Sealant as manufactured by Saint-Gobain Company..

16″ x 16″ Sound Rated Access Panel – STC Series

16
Check Price for 16

16″ x 16″ Sound – Rated Access Panel STC – JL Industries Introduces the First STC-Rated Access Panel with an STC 47 Rating Meet Noise Containment and Sound Transmission Blocking Requirements for Walls with the US Patent Pending STC Panel Rated by Intertek Warnock Hersey http://www.bestaccessdoors.com/content/specs/STC.pdf Technical Data Submittal Sheet (STC) HIPAA Requirements for Patient Privacy LEED Enhanced Acoustical Performance Credits for Schools Proper Installation is Critical to Create the STC-Rated Sound Barrier. For best results, Activatar Construction Products Group, Inc. (ACPG) Recommends the use of Green Glue Acoustic Sealant as manufactured by Saint-Gobain Company..

12″ x 12″ Sound Rated Access Panel – STC Series

12
Check Price for 12

12″ x 12″ Sound – Rated Access Panel STC – JL Industries Introduces the First STC-Rated Access Panel with an STC 47 Rating Meet Noise Containment and Sound Transmission Blocking Requirements for Walls with the US Patent Pending STC Panel Rated by Intertek Warnock Hersey http://www.bestaccessdoors.com/content/specs/STC.pdf Technical Data Submittal Sheet (STC) HIPAA Requirements for Patient Privacy LEED Enhanced Acoustical Performance Credits for Schools Proper Installation is Critical to Create the STC-Rated Sound Barrier. For best results, Activatar Construction Products Group, Inc. (ACPG) Recommends the use of Green Glue Acoustic Sealant as manufactured by Saint-Gobain Company..

Recent Entries »